For invited Trial sysops · Build 6.6.247.0
AR-Cluster .247 Trial
For production installations, use the Stable download page.
Install a new node or upgrade an existing AR-Cluster installation.
Existing Trial installations can use Tools → Check for Updates. The updater/support ZIP is also available separately.
Install or upgrade one instance
- Back up an existing node and record its callsign and installation and data paths.
- Run Setup from a folder outside the installation. Select a fresh folder or the exact existing instance to upgrade.
- Review the installer result, then start ARC6 under the selected operator account. Confirm the version, listeners, settings and live spot flow.
Changes since 6.6.205.0
- Read-only API. Recent-spots retains its existing response and snapshot pagination. The separate spot-observations GET adds cursor-based incremental reads with stable IDs within a cache epoch. Collectors should obtain a fresh cursor after a cache reset. Requested by Attila Holop, HA2NA. Implementation and checks by NG7M.
- API startup and performance. Recent history warms from committed SQLite rows, bounded by configured DX memory retention and 100,000 rows. Startup logs report the warmup count and time. Short recent-spots requests apply the time cutoff before copying and projecting rows. Scan-guard diagnostics are rate limited. Implementation and checks by NG7M.
- Callsign data. Resolve FCC and Canadian lookups using CTY entities, skip foreign lookups, and update FCC/VE indexes through maintenance or on demand. Implementation and checks by NG7M.
- Setup and PC migration. Added listener-release safeguards during upgrades, clearer progress text for existing SQLite databases, elevation for migration, destination log-path rebasing, and desktop shortcut fixes. Migration feedback from Dave K1TTT. Implementation and checks by NG7M.
- Monitoring and logs. Improved Log Viewer search, scrolling and closing during live refresh. Added Security Monitor filters, reduced refresh work, and made User Session History modeless. Direct Telnet Spot Feed per-spot INFO logging has its own option and defaults to off. Log Viewer reports and Security Monitor suggestions from Dave K1TTT. Implementation and checks by NG7M.
- Security. Apply persistent login and spot-content blocks before downstream work and accounting. Added an optional incoming Telnet listener password. Block-order feedback from Dave K1TTT. Implementation and checks by NG7M.
- DX commands. Added per-user beacon output control, beacon filters and beacon history queries. Saved DX filters display compact frequency shorthand and CLI help covers the new options. Filter display feedback from Dave N3RD. Implementation and checks by NG7M.
- Peer interoperability. Report the current ARC6.6 version through PC18 and PC92K, retain the legacy identity option, show reported software in network-map tooltips, and improve PC92 topology handling. PC92 guidance and review from Dirk G1TLH and Kin EA3CV. Implementation and checks by NG7M.
Download integrity
Setup SHA-256 07AAC1F01E235122F7C52DD54CDE4D1CFBFAFAD586701ABB0699BA30827AFD61
Updater ZIP SHA-256 3FA81888CF0C977A59DB4F5CC6EA326AC63CEDA8239CCD3640D6F24D08722215
Matching source and third-party notices for 6.6.247.0
Source ZIP SHA-256 A03C47F444D6CDE4A19D2BD6C900D556F959FEFED7B0CECCF123DE6D1D8069D4