AR-CLUSTER 6.6.176.0 - operator manual test for NC7J-3

Alan Rovner K7AR requirements / NG7M: optional per-instance read-only HTTP JSON
API, disabled by default on loopback, configurable port3994 and independent
protected read token. Bounded authenticated status/spots/WWV-WCY, typed filters,
UTC/kHz/source attribution and display-mode/skimmer grouping. Setup applies
API enable/disable/rebind/rotation without restarting ARC. API reads committed
history without forcing saves; failures do not stop normal node processing.
The website remains on its existing data adapter until separately migrated.
NG7M: Network Map reported identity flag labels, report age/direct connection
origin, local uptime/direct-peer count and snapshot age. Queued installer sole
registered-instance preselection/recovery-required visibility remain unimplemented
and deferred; this build retains the existing .175 selector/recovery behavior.
FULL, RBN local-only delivery, existing identity/data/config safeguards preserved.
Implementation and isolated validation: NG7M. UI/target-host acceptance pending.

NC7J-3 OPERATOR CHECKLIST
Before installing, ask to stop ONLY the dedicated K7AR-WebCluster IIS pool;
do not stop IIS or other pools. Use ordinary selected-instance Setup/recovery.
After healthy ARC startup, ask to restart that pool and verify website traffic.
API is initially disabled. After installation, separately provision its exact
per-account URL reservation and configure its token/unique port before enabling.
Do not put the token into browser code, URLs or logs. See docs/READ-ONLY-API.md.
Check API apply/error behavior and normal real spot traffic, and new map tooltips.
No website adapter change, live node installation, feed promotion or publication
is performed by preparing this kit. Private operator build only.

Previous local and published release notes follow:
AR-CLUSTER 6.6.175.0 - operator manual test

NG7M: SET DX FILTER DEFAULT restores the current Telnet listener's current
nonblank validated default; failure preserves the user's filter. Help updated.
History saves use 500 pending rows/cache or a 10-second periodic deadline.
Durable FULL, bounded transactions and retries retained.
K1TTT reports / NG7M: successful history saves consolidated into minute INFO
summaries; per-save detail DEBUG, errors immediate. Log Viewer shows Component.Method.
Failed DNS reports target without secondary null error. Indirect map nodes show
reported software/version/build; green requires explicit ARC6.6 evidence.
NG7M: local map tooltip includes count source and snapshot UTC.
K1TTT experience / NG7M: conversion copy/validation progress and table timings.
Conversion validation, recovery and batching unchanged. No optimize or connection
reuse change. Existing .174 features retained. Operator testing only.

SPDX-License-Identifier: GPL-3.0-or-later
Copyright (c) 2026 Max George (NG7M). See COPYING and CREDITS.txt.
