# ARC6 6.6.93.0 x64 — unpublished NC7J manual test, October 1, 2026

Extract the complete ZIP to a short writable folder and run ARC6-Setup.exe.
Select the intended existing instance and verify its exact path/callsign.
Keep that instance stopped during the update. Retain its upgrade backup.
This is a private test kit: the published .92 and update channel are unchanged.

Manual acceptance checklist:
- Review Setup labels, bold summaries and lower help; RBN row selection should
  select only, with its ellipsis/button opening the editor. PublishInfo is hidden.
- Check Continent, Country Prefix and State / Province; verify US/Canadian
  lookup results, missing-data blanks and N/A for other countries.
- Check a standard saved HamQTH HTTP URL migrated to HTTPS; custom endpoints
  are preserved. Inspect upgrade history. Application log rollover is 100 MB
  plus daily; existing saved WCY result limits are preserved (new default 24).
- Confirm About shows 6.6.93.0 and the intended callsign/SSID.
- Check existing profiles, filters, database locations, listeners and peers.
- Press Enter; test CR-only SpotCollector post-login commands:
  sh dx 100 @<enter>sh wwv<enter>
  Confirm both commands execute in order and each ends with one prompt.
- Test HELP, SHOW DX, SHOW LOG and an unknown command for one final prompt.
  Verify full login callsign/SSID and UTC time; live spots add no prompts.
- Inspect RBN FT settings; choose port 7002 explicitly to receive TXOffset.
  Existing 7001 settings are preserved. Check low, wide and missing offsets.
  RBN/skimmer traffic remains local-only, never forwarded to cluster peers.
- Open Tools > User Session History, reconnect a test user, inspect durations
  and reasons. History is memory-only and clears on restart; no blocking.
- Check local filter export, configured node identity and Help/About changes.
- Add {LATESTWCY} to a trial welcome file if desired; absent history is blank.
- Observe PC11/PC61 peer traffic and retain logs/full dump if a crash recurs.

UI, upgrade and live acceptance are operator-owned. No automated upgrade
rehearsal or UI walkthrough was performed. Earlier release notes follow.

# ARC6 6.6.90.0 x64 trial - .NET 4.8 / Server 2012 R2 canary

Requires .NET Framework 4.8 or newer and Windows PowerShell 5.1 Desktop.
Setup checks the actual PowerShell version and gives WMF guidance if needed.
Server 2012 R2 compatibility is prepared for manual testing, not certified.
Extract the complete ZIP; run ARC6-Setup.exe against the existing licensed
installation. Confirm identity/path and keep ARC6 stopped first.
Check version, data/license preservation, listeners, peers and real spot flow.
Includes informational FT/CT1BOH filter warnings; filter terms remain unchanged.
Earlier historical requirements below are superseded by this entry.

# ARC6 6.6.83.0 x64 trial

Fixes RBN reconnect on unchanged Save when the inherited login handshake strips
the running callsign SSID. Equivalent host spelling no longer causes a restart.
Actual endpoint, role, login/password and enablement changes still apply.
After upgrade, Save unchanged choices and check connection time stays intact.
The .82 modal-loop fix and scrollable dialog layout are retained.
Manual acceptance remains operator-owned.

# ARC6 6.6.82.0 x64 trial - NC7J-3 dialog repair

Fixes the RBN Setup row reopening loop after Cancel. Opening is reserved before
the queued callback and suppressed through dialog dismissal and grid refresh.
RBN sections now size to contents, scroll when needed, and keep Save/Cancel
outside the scrolling area. Verify Cancel, X, Escape and Save return to Setup;
then reopen deliberately. Inspect both feed groups at your Windows scaling.
All custom endpoint/feed policies from .81 remain. Manual UI acceptance pending.

Earlier retained notes follow.

# ARC6 6.6.81.0 x64 trial - NC7J-3 operator handoff

Custom RBN endpoints now accept DNS hostnames, IPv4/IPv6 addresses and ports
1-65535. CW / RTTY and FT Modes are saved as explicit feed roles, preserving
read-only ingestion and local-user-only delivery at custom endpoints.
Changed nonstandard endpoints require confirmation; Restore defaults returns
the standard host/port. Unchanged custom endpoints do not repeat the warning.
One enabled feed per role per instance is allowed. The two roles cannot use
the same endpoint. A local relay may intentionally serve several instances;
coordinate its upstream subscriptions yourself.

Selecting Setup's RBN Feeds row opens the dialog; its value also has an
ellipsis editor. The bottom button and Tools menu remain available.
Check the row and dialog layout, warning/Cancel behavior, Restore defaults,
endpoint and role persistence after restart, and real spot flow on NC7J-3.
Download through Trial, confirm the installation and keep ARC6 stopped.
Manual UI and live upgrade acceptance remain operator-owned.

Earlier retained milestone notes follow; this entry takes precedence.

# ARC6 6.6.80.0 x64 trial - NC7J-3 operator handoff

This trial adds Tools > RBN Feeds: CW / RTTY (7000) and FT Modes (7001).
Existing feed settings and IDs are preserved. One enabled RBN feed per port
is permitted per instance, regardless of hostname or old I/O label.
On first startup, review disabled/missing FT Modes and explicitly save your
choice. Enabled CW suggests enabling FT; Decide later retains a reminder.
Duplicate groups are held until you choose one feed. The other-instance
advisory reports saved settings; coordinate subscriptions across instances.
RBN ingestion stays read-only and skimmer spots remain local-user-only.

Use NC7J-3 Tools > Check for Updates > Trial. Check the selected installation,
keep ARC6 stopped, and use ARC6-Setup.exe for the verified upgrade.
Setup now repeats the selected/resulting directory and uses larger red
wrench artwork. Fresh-instance installation remains deferred.

After restarting, confirm 6.6.80.0, review both RBN feeds, save your intended
choice, and confirm it survives restart. Check real spot flow, user filters,
ordinary connections and the other instances. Test Decide later/reminder
and menu entry points when practical. UI and live acceptance are yours;
no automated upgrade rehearsal or UI walkthrough was performed.

The following retained notes describe prior milestones; the current entry
above and INPLACE-QUICKSTART.txt take precedence for this upgrade.

# ARC6 6.6.78.0 x64 trial - operator handoff

The .78 trial fixes the confirmed .77 Inbound row-formatting exception.
Repeat ARC4 selection and switch filters on K1TTT. Comparable formatting,
tooltip and action paths in Outbound/Disabled use the same bound-row fix.
Shared connection menus now open the log viewer filtered by full callsign.
The capture checkbox remains with a shorter label and explanatory tooltip.

The .77 candidate addresses the reported connection-menu crash and menu
parity, Health width and update-age display, and finish-page branding.
The menu lifetime bug is corrected; confirmation of the production crash
cause still needs crash evidence or the operator's manual retest. Test on
NC7J-3 before upgrading K1TTT or other busy instances. Check inbound and
outbound Connection/Configuration actions, lookups, and Health pin/unpin.

The 6.6.76 trial includes clearer Stable/Trial update status, repaired
Setup progress stages and final-page control placement. NC7J-3 can check
from 6.6.75, while other instances still on 6.6.73 can validate this kit
through its retained compatibility filenames. Operator UI and live upgrade
acceptance are required before wider rollout.

The installed 6.6.73 downloader requires the former maintenance and worker
filenames. This transition kit includes byte-identical compatibility copies
under those names, while Setup uses the clearer current names. The 6.6.74.0
trial ZIP lacked these copies and was refused before origin binding or any
upgrade action. 6.6.75.0 supersedes it on the trial feed.

New in .74: ARC6-Setup.exe verifies the selected installation and its
running process by executable path, PID and start time. It can ask only that
instance to close normally, then checks it is stopped before maintenance.
Setup does not force-kill processes. After a successful upgrade, an
unchecked option can start the upgraded instance when Setup closes, using
the committed installation path. ARC6-Maintenance.exe holds the advanced
recovery, rollback and data actions; ARC6-Setup-Worker.exe is internal.
The .73 downloader binds the installation but does not carry process start
time, so .74 Setup probes and rechecks it before any stop request.

New in .73: the updated Check for Updates dialog calls the action Download
verified update and opens ARC6-Setup.exe directly after verification. The
Inno wizard overlays the startup-splash wording, keeps Next disabled until
the operator confirms the selected instance is
stopped, preserves existing desktop shortcuts automatically, shows the
expected prerequisite delay, and adds an Open upgrade log button on
completion. Setup does not stop or start an instance. The .72 downloader
still opens the ready folder for this .73 update; direct launch is available
from .73 onward. Manual UI and upgrade acceptance remain operator-owned.

New in .72: the AR-Cluster-branded Inno wizard handles target selection,
confirmation, live progress and completion itself. It checks .NET Framework
4.8.1 and PowerShell availability before starting; x64 Windows 10 build
19042 or newer is required. If .NET is missing, Setup offers the verified
Microsoft installer, closes after it runs, and directs a restart when
Microsoft requires one. Rerun ARC6 Setup afterward. The existing journaled
worker performs the upgrade through ARC6-Upgrade-Headless.exe; the
ARC6-Upgrade.exe window does not open during the ordinary flow. Stop the
instance before running ARC6-Setup.exe from the
verified ready kit. Keep ARC6-Upgrade.exe for advanced recovery, rollback
and optional ProgramData actions. Fresh-instance installation is not yet
part of this trial. Publication and manual UI/upgrade acceptance are separate.

New in .71: the verified kit includes ARC6-Setup.exe, a familiar Inno
Setup entry point for an existing instance. Stop the instance first, then run ARC6-Setup.exe from the ready kit folder.
It opens a guided upgrade backed by the existing journaled worker; the
target path remains locked for a same-machine Check for Updates download.
The separate ARC6-Upgrade.exe remains available for interruption recovery,
rollback and optional ProgramData actions. Fresh-instance installation is
not enabled in this trial. The .70 downloader's generated handoff text still
names ARC6-Upgrade.exe; the .71 test used ARC6-Setup.exe as instructed
in that kit. The operator completed NC7J-3's .71 upgrade successfully.

New in .70: reused DX command workers no longer fail while setting their
thread name. Unexpected command errors log the requester callsign when
available. CT1BOH callsign distance uses less allocation with unchanged
results in local parity fixtures. Check for Updates opens the verified ready
folder automatically after download. The .69 upgrader elevation and origin
binding behavior below is retained. The .70 trial was published and all
NC7J and K1TTT instances were upgraded by the operator.

New in .69: ARC6-Upgrade.exe requests administrator privileges through its
embedded Windows application manifest before showing the maintenance window.
This avoids a permissions error late in an upgrade on a non-elevated account.
When the downloading ARC6 records its installation, the upgrader selects and
locks that path; Browse is disabled. The installed .67 downloader lacks this
record, so select NC7J-3's installation manually for the .67-to-.69 test.
Standalone or moved kits also allow manual selection. Hidden AppData path
checks are corrected so a downloaded kit can run from its ready folder.
The .68 download currently on NC7J-3 is unchanged. On hosts needing
elevation, start that older upgrader with Run as administrator.
The .69 endpoint was published and the operator reports all instances on .69.

New in .68: unavailable feeds say release information could not be loaded.
The intended test is a manually approved trial feed offering .68 to a running
.67 x64 instance; reading notes, confirming, downloading and verifying
the kit occur before any stopped-server upgrade. Stable remains unpublished.
Endpoint publication and live acceptance are separate gates.

New in .67: Tools > Check for Updates has stable/trial selection, plain-text
release notes and opt-in HTTPS/SHA-256 verified kit download. A ready kit
opens in Explorer; stop the current instance before running
ARC6-Upgrade.exe. The older incomplete updater is removed. Forced updates
are disabled. Endpoint publication is controlled separately from the kit.
Manual UI, real endpoint delivery, installation and runtime checks remain
operator-owned. Check failures leave the running node unchanged.

New in .66: the upgrade-window action is labeled Return to legacy data
folder. Its tooltip explains the binding switch and retained ProgramData
copy. This changes wording only, not the data-move operation.

New in .65: Complete interrupted data move is reserved for an initial move
interrupted before its binding was published. An already committed binding
reports that nothing changed. Return to legacy data retains the ProgramData
copy and binding record. Restore ProgramData copy verifies that retained
binding, owner, logging policy and both databases before rebinding the
current ProgramData copy; it does not require unchanged migration-time file
hashes. Changes made while running from legacy data are not merged back.
For an NC7J-5 reversal test, keep ARC6 stopped between Return and Restore.

New in .64: Tools > Open Data Files Folder opens the data root this running
instance selected at startup. A bound instance opens its ProgramData instance
root; an unbound instance opens its installation root. This is a read-only
navigation action and does not change bindings or move files.

New in .63: the same trial kit carries the .62 PC92 structural-edge CPU
change, the negotiated PC9X tooltip and larger Setup/My Connections fonts,
and explicit ProgramData actions in the upgrade window. Upgrade never moves
data automatically. After a successful upgrade, select the current installed
directory, leave ARC6 stopped, then choose Move data to
ProgramData. The window also offers Recover data move and Return to legacy
data. A return does not merge changes made while bound to ProgramData. The
existing migration script remains available for recovery and diagnostics.

New in .62: K1TTT's .61 main-process trace contained 6,345 CPU samples in
one minute versus 8,040 on .58, with PC92 receive/projection still the
largest path. The route snapshot portion fell from 2,129 to 1,011 samples,
but genuine changed-edge updates still regrouped each origin's edges per
direct peer. This build groups structural edges once when they change and
reuses that index for route traversal. In a local 1,000-edge/30-path fixture,
30 changed-C/route-snapshot cycles measured 201 ms on .61 and 98 ms with
this change, producing identical route output. A sparse one-edge fixture
showed no benefit. These timings do not predict live K1TTT CPU. Compare .61
and .62 only after the network has settled. See K1TTT-CPU-TRACE-66610.md.

New in .61: the reachable-node list is reused while route membership is
unchanged. This avoids repeating an origin/edge scan for projection and
legacy topology filtering after identity-only PC92 changes. In the isolated
200-origin/30-peer fixture, 100 identity-only C updates with route and node
queries took 70 ms on the committed .59 core and 1 ms with the combined
.60/.61 changes. This is a fixture result, not a predicted live CPU value.
The .60 local kit was superseded before field installation. Use the .61 kit
for the next operator-owned .58-to-.61 comparison.

New in .60: route snapshots are reused when a PC92 update changes display
identity or local-user membership without changing session, ingress path or
relationship reachability. Connect, disconnect, new/removed edges and expiry
invalidate the cache. An isolated 200-origin/30-peer fixture measured 100
identity-only C updates plus route queries at 31 ms with the .59 core and
1 ms with this change; those timings do not predict live CPU. DX fan-out
also skips FT SQL filter evaluation for recipients whose DX output is off
or whose server output already suppresses skimmer spots. The output rules
are unchanged. This trial includes the .59 unchanged-C/A/D projection fix;
.59 was prepared locally but not field installed. Leave K1TTT's legacy data
layout intact for the .58-to-.60 comparison. No live .60 result is claimed.

New in .59: K1TTT's settled .58 PerfView trace had about 8,040 main-process
CPU samples in one minute, compared with about 22,894 on .57. PC92 receive
processing still led to full projection for accepted C/A/D messages with
unchanged topology. This build keeps replay, lease and wire handling, but
skips reprojection when edges, identities and ingress paths are identical.
The isolated 1,000-edge fixture reduced 300 identical C updates from 345 ms
and 300 projection invalidations to 276 ms and zero invalidations. Fixture
timing does not predict K1TTT's live CPU. Compare five-minute CPU, peer count,
origins and queue wait after the .59 network settles; leave K1TTT on its
legacy data layout. See K1TTT-CPU-TRACE-66580.md. No live .59 result is
claimed.

New in .58: after K1TTT's .57 CPU settled near 8%, a 60-second PerfView
trace found PC92 projection in about half of its main process CPU samples.
This build avoids the full projection on stable one-second maintenance ticks,
prunes reachability only after topology removal or expiry, and handles PC92 K
lease/identity updates without cloning origin edges. Keep K1TTT's current
legacy data layout for the comparison. Record Health five-minute CPU, peer
count, `SH/PC9X` origins and queue wait after the network settles. See
K1TTT-CPU-TRACE-66570.md. K1TTT's subsequent .58 Health CPU settled near
2%; see K1TTT-CPU-TRACE-66580.md for the private trace comparison.

New in .57: exact duplicate PC92 packets only rebuild the node/user view when
they add an alternate path. Accepted keepalives with unchanged identity and
route queries do not rebuild that view. K1TTT's .56 view grew from 173 to
312 origins as duplicates reached 19,003 and the protocol queue peak wait
reached 12.362 seconds; its five-minute CPU reading rose to about 16%.
That build targeted redundant projection work; K1TTT's settled .57 Health
CPU was about 8% before the present change.

New in .56: PC92 route discovery uses a queue-based traversal. The change is
intended to reduce the topology-projection CPU cost identified in K1TTT's
.54 trace. It does not change peer configuration, routing rules, or wire
messages. The .54 trace and local validation are documented in
K1TTT-CPU-TRACE-20260928.md.

NC7J-3 is already a .55 ProgramData canary. Its existing verified binding
should continue to select ProgramData after a later .65 executable upgrade;
do not rerun migration for an already bound installation.

## Optional ProgramData migration for a new canary

The .65 executable retains legacy paths unless an explicit verified binding
exists. For a later canary authorized by the operator, stop ARC6, upgrade using the kit, and leave it stopped. In an elevated Windows PowerShell 5.1
window from the extracted kit, run:

  .\migrate-programdata.ps1 -InstallationDirectory '<exact installation root>' -ConfirmStopped

The migration preserves the legacy files, copies and hashes mutable data,
opens both copied SQL CE databases, and publishes the instance binding last.
Only after a successful `Committed` result should ARC6 be started. Confirm
the installed version, licensed call, listeners, peers, feeds, logs and
SHOW/DX behavior. UI checks remain manual and operator-owned. Do not migrate
another node until the canary has been accepted.

If interrupted, leave ARC6 stopped and run the same script with both
`-Mode Recover` and `-ConfirmStopped` for the same installation root. An interruption before instance publication
leaves legacy operation unbound; review the staged copy, then rerun Migrate.
To return to the preserved legacy data, stop ARC6 and run with
`-Mode Rollback -ConfirmStopped` before starting it. Bound data and the removed
binding are retained for review; changes made while bound are not merged into
legacy data. Remove the binding before using an older upgrade kit's rollback.
To reverse that return, leave ARC6 stopped and choose Restore ProgramData
copy in the .65 upgrade window (or run `-Mode Rebind -ConfirmStopped`). This
verifies the retained binding and current databases before publication.
Changes made after starting the legacy copy are not merged into ProgramData.

The migration has been checked on isolated copies, including interruption,
recovery, rollback, database opens and log placement. No live installation,
automated upgrade rehearsal or UI acceptance is claimed.

## Earlier trial changes

New in 6.6.54: Setup immediately replaces enabled outbound clients whose saved
identity, endpoint, type, or password changed, while preserving unchanged live
clients. Listener enable/disable remains live; other listener edits report that
ARC6 must restart. The comparison excludes the inherited listener IpAddress
field because accepted Telnet sessions overwrite it with each remote endpoint.

Skimmer DX spotters now retain a 28-character station identity plus a two-digit
SSID and terminal -# marker, up to 33 characters, through parsing, shared DX
processing, SQL CE schema migration, realtime history and user output. Invalid
multi-digit portable call areas remain rejected.

The maintained solution now opens from repository-root ArCluster.sln
with product projects under src. The .54 build included an inactive
ProgramData path context; .55 activates it only after the explicit migration
publishes a verified binding for that installation.

Local validation for .54 uses VS2026 x64 Release and x86 Debug builds, focused
path/binding, I/O refresh and RBN fixtures, broader protocol checks and the x64
package audit. UI and live acceptance remain operator-owned.

New in 6.6.53: terminal -# skimmer spotter validation is consistent between
Telnet RBN input and shared spot processing, including PC11 and RBN playback.
Valid numeric skimmer SSIDs and portable call areas remain accepted; embedded
or repeated markers and invalid underlying calls are rejected. Skimmer spots
remain local-user-only and must not be forwarded to cluster peers.

Manual trial: install on NC7J-3/-5/-7 during the contest, observe process
stability, RBN reception, local spot delivery, and peer traffic through the
contest end. Consider main NC7J only after that soak and operator review.
UI and live protocol acceptance are operator-owned. ProgramData remains inactive.

Local validation for .53: VS2026 x64 Release and x86 Debug builds, 216 captured
RBN spots and 1,245 focused checks, and x64 package audit (60 files) passed.
No automated upgrade rehearsal or UI walkthrough was run.

New in 6.6.52: Telnet callsigns follow DXSpider-style prefix/digit/suffix
validation, normalize -0/-00, accept supported portable suffixes and up to 28
characters, with callbook lookup using the base callsign. PC92 A/D reception
accepts both the historical empty first slot and Dirk G1TLH's corrected
single-member or user-first first slot. Locally generated A/D continues to use
the existing explicit node first slot pending receiver-side field validation.

Manual trial: install on NC7J-3 first; confirm login/lookup behavior and PC92
peer topology before rolling out to other NC7J instances. UI and live protocol
acceptance are operator-owned. ProgramData migration remains inactive.

Local validation: VS2022 x64 Release build; actual-assembly PC9X integration
211 checks; PC92 codec 918 and topology 541 checks; numeric-SSID loopback
fixture completed; package audit 60 files. A separate broader Telnet write
fixture fails on its saved-filter fallback text expectation even in a fresh
disposable run. No automated upgrade rehearsal or UI walkthrough was run.

New in 6.6.51: log-viewer text filters and keyboard-driven combo selections use
a short settle interval instead of re-filtering the retained live log for every
intermediate edit. Enter, leaving a text field, and closing a combo apply at once;
live log ingestion continues under the prior applied filter while editing.

Retained from 6.6.50: locally generated PC92 C/A/D membership records use the bare
node identity while K retains the historical 5499 software identifier. Native
transit PC92 payloads remain unchanged apart from hop count.

Retained from 6.6.49: topology learned through PC92 remains available to ARC6 local
displays and routing, but is no longer translated into PC16/17/19/21 for
legacy PCxx or ARC4 peers. Legacy initialization still exports ARC6's real
local/direct legacy tree, and native legacy sentences continue to relay to
other legacy peers with their hop count reduced. This prevents a PC9X network
from being duplicated continuously into every legacy session.

Retained from 6.6.48: the installer ensures the DX SQL CE connection supports databases
up to 4091 MiB during migration and after publication. Existing higher limits
are replaced and duplicate maximum-size entries are normalized.

Retained from 6.6.47: valid PC51 keepalive requests addressed to the local node receive
an immediate PC51 reply on the same connection. Replies, malformed frames and
requests for other nodes are ignored. Health auto-hide drawing releases its
temporary native GDI+ transforms after each repaint. This corrects a confirmed
resource leak but does not claim to identify the cause of the September 25
NC7J heap-corruption crash. ProgramData migration remains inactive.

New in 6.6.46: ARC6 node login advertises the exact `ARC_WCY_1` capability.
When both ends advertise it, a PC73/WCY report is also relayed as semantic WCY
data over ARX. Mixed .45/.46 and older ARX links continue without WCY. The
existing WCY report-hour key suppresses duplicates when a node receives the
same report from direct PC73 and ARX paths. The connection log records whether
WCY was enabled for each ARX peer. This build also excludes a same-callsign
legacy child from ARC's local PC92 membership and preserves every received PC93
field during transit while decrementing only its hop count.

New in 6.6.45: accepted transit PC92 and old-style PC16/17/19/21 sentences
are forwarded without rewriting any content except the hop value and are not
returned to their source. Learned external routing is no longer emitted as a
series of locally regenerated PC92 C records. ARC's own C contains only its
direct peers and users and refreshes hourly with K. PC11/PC61 forwarding
preserves `/P` callsigns, punctuation, and comments. ProgramData migration
remains inactive.

New in 6.6.44: PC92 topology learned through legacy PCxx retains the owning
node callsign instead of being rebadged as the local ARC6.6 gateway. Initial
snapshots use atomic C records; individual connections and disconnections use
A and D. Native PC92 forwarding continues to preserve its original origin,
identifier and payload while reducing only the hop count. Atomic C input now
supports large nodes up to the bounded 1 MiB wire limit. This build does not
activate the planned ProgramData migration; every runtime path remains in its
6.6.43 location.

New in 6.6.43: the upgrade widens saved user-profile storage beyond 4,000
characters before auditing profiles. Unreadable profiles such as a legacy row
truncated at that old boundary are reported as RecoverOnLogin and no longer
block the upgrade. The original row remains preserved until that callsign logs
in; ARC6 then uses the defaults from the actual listener and a normal session
save replaces the unreadable XML. SH/WCY headings are aligned with its rows.

New in 6.6.42: upgraded installations can execute PC73 and every WCY command
even when their preserved ArcServerDi.xml predates WCY. In Sysop Settings,
PCxx / PC9X now includes "PC9X public IPv4 address or hostname". A literal
public IPv4 applies directly. A hostname is resolved without blocking startup,
refreshed every 15 minutes, and keeps the last valid address during a DNS
failure. Blank uses automatic external discovery. Verify SH/WCY, SHOW/WCY,
HELP WCY, an incoming hourly PC73, and the address-source log entry on NC7J-3.

New in 6.6.41: PC92 message identifiers use DXSpider-compatible hundredths,
and PC92 K records include the discovered public IPv4 address when safe. PC18
advertisement records whether PC9X was offered or the exact reason it was
omitted. Ordinary PCxx logins on ARC4-compatible listeners can negotiate PC9X;
explicit ARC4 logins remain legacy. WCY has independent hourly storage,
delivery, PC73 forwarding, and WWV-style commands. Pending unauthenticated
Telnet sockets no longer emit false PC17 records. The original Health tab
status icon is restored. My Connections now retains active sessions while its
dock window is closed and replays them when reopened, so healthy persistent
peers and RBN feeds do not disappear from the tree. For NC7J-3, reconnect
NG7M-1 after startup and retain the PC18, PC92 A/K, PC20 and PC22 exchange plus
SHOW PC9X output. UI acceptance and live peer interoperability remain
operator-owned.

New in 6.6.40: Logging Options shows Application diagnostics at the top,
with a saved WARN/INFO/DEBUG minimum for ArcServer.log, then separate bordered
Protocol and I/O traffic groups. Each instance reads and preserves its own
log4net XML; do not copy logging XML or ArcServerCfg.xml between installations.
On NC7J, with RBN switches off, check that no new RBN rows appear in either
ProtocolTraffic.log or ArcServer.log while the feeds remain connected. Verify
the same behavior on NC7J-3, -5, and -7. Change the application minimum once
on a chosen instance, check its status changes without a restart, then restore
the preferred level. Also check Health's updated age starts at zero and the
splash credits Terry Gerdes as AB5K (SK). UI and live acceptance are yours.

New in 6.6.39: Health opens wider, displays a one-second countdown to the
next full refresh, and uses half-height mini graphs. I/O capture switches
include separate CW/RTTY and FT RBN feeds. Combined Log Viewer displays
Application and I/O traffic from separate files, including older lines;
unchecked RBN switches block *new* feed capture even when temporary
per-connection capture is enabled. My Connections has a right-click TCP
disconnect for users and peers, with confirmation. The DX history upgrade
preflight now streams large tables. The original Health auto-hide tab icon
artwork is not yet restored; check the current status tab during manual UI
review. No automated UI acceptance is claimed.

New in 6.6.38: Logging Options has separate, initially off CW/RTTY RBN and
FT4/FT8 RBN capture choices. Both directions of a selected feed are recorded;
Telnet RX/TX now clearly names connected-user traffic. All 11 saved diagnostic
choices are restored on startup. The connection dialog's temporary capture
choice overrides the global choices only until that connection disconnects.
For the manual check, record checkbox states, restart the instance, reopen
Logging Options, and compare. With RBN capture off, check for *new* lines in
ProtocolTraffic.log while real feed traffic arrives; older viewer lines remain.
Then enable one RBN choice at a time and confirm only the selected feed appears
with its RBN-CWRTTY or RBN-FT protocol label. Turn verbose capture off when done.

New in 6.6.37: Health content returns to its prior 10.25-point regular font
with bold headings. The right-side auto-hide tab uses a larger bold font and
more prominent red/green status swatches. Manual visual acceptance is pending.

New in 6.6.36: Logging Options uses a modeless window with immediately saved
checkboxes and a close button. The Log Viewer severity selection is explicitly
an exact-level display filter. TCP connection failure messages carry the
callsign and remote endpoint when known. Health text, sample age, interval
placement, tab status symbol, splash duration, and default width are refined.
The operator owns manual UI and live log acceptance.

New in 6.6.35: DockPanel Suite is upgraded from legacy 2.5 to maintained
3.1.1 and explicitly uses its VS2015 light theme. ZedGraph and Visual Basic
Power Packs are replaced by native WinForms controls; the upgrade removes
their obsolete DLLs from its isolated stage before publication. Health now
uses the docking library's native close and auto-hide behavior without the
custom Collapse button. ARC6 has no saved DockPanel layout to migrate; its
layout is built by the application at startup. The operator should manually
check the Health tab, My Connections, Inbound/Outbound, logs, embedded and
standalone clients, DX/skimmer graphs, and updater separator lines. Automated
UI validation is intentionally excluded by trial policy.

New in 6.6.34: skimmer comments are exempt from bad-word filtering because
they contain decoder metadata. Ordinary spot comments retain the filter.
No logging behavior changed; investigate Dave's reported outbound Telnet
logging separately when an actual log line and its file are available.

Kit revision 2 fixes recovery routing after a completed x64 relocation. Dave's
first recovery attempt used the older 6.6.33 revision 2 kit, which treated the
completed relocation as the operation to recover and refused it. The revised
kit forwards Upgrade, Recover, and Rollback to the active native Program Files
installation. It does not change the 6.6.34 server binaries.

Kit revision 3 addresses Dave's next failure: Windows denied renaming the
active native Program Files installation directory even though recovery could
restore it. Publication now keeps that root directory in place, copies the
verified current installation to rollback storage, and replaces the root's
contents from the validated stage. Recovery uses the same root-preserving
method. Server binaries remain the audited 6.6.34 build.

Kit revision 2: Dave's Windows 10 run passed the host and inner upgrade checks,
then failed while moving the old installation to a sibling rollback folder.
Read-only checks show both old and upgraded directories present, a pending
relocation marker, and Administrator Full Control on the old folder and its
parent. The exact cause of the move denial is unconfirmed. This revision
leaves the old installation at its original path as the rollback copy. Run
Upgrade with this revision against the original path after stopping that
instance; it verifies both directories, then completes the
shortcut and firewall path changes without migrating data again. Do not run
either executable before finalization reports success. Preserve the support
ZIP if validation stops or another step fails. The CW and Digi sibling
instances were observed running separately and need not be stopped for this
targeted operation.

New in 6.6.33: Dave's 6.6.32 support log showed host checks passing, then
ArcEngine.dll failing to load with FileLoadException 0x80131515 before the
license reader ran. A locally marked copy of that exact DLL reproduced the
failure; clearing its Windows download mark restored loading. This kit clears
the mark only on hash-verified trial binaries in the isolated working copy.
It does not change the license reader, license file, installed binaries, or
normal .NET assembly trust settings. Dave's supplied full 6.1 installation
ZIP contains the same previously validated License.art hash, two distinct
relative SQL CE databases inside the installation, and no linked files.
It is a read-only local fixture, not an automated upgrade rehearsal. The
next live gate is Dave's manual Windows 10 upgrade attempt; retain the support
ZIP if another prerequisite fails. Windows 10 feature release and free disk
space remain to be confirmed on his host.

New in 6.6.32: peer PC11 spots wait up to two seconds for a matching PC61
when a PC9x peer is live. Frequency, DX call, report minute, spotter (without
numeric SSID) and origin must agree; comments may differ. Valid PC61 replaces
the waiting PC11. A timeout releases PC11 through normal spot processing.
The waiting set is bounded and SHOW PC9X reports pending/promoted/expired/
repeated counts. Ordinary direct-user spots are unaffected. Observe real
PC11/PC61 pairs and the counters on NC7J-3 after installation.

New in 6.6.31: PC61 retains a validated received spotter IP through normal
spot processing and sends PC61 to negotiated PC9x peers with the decremented
hop budget. A direct local user spot can use that user's actual incoming
socket IP. Unknown or invalid IPs stay PC11, as do all legacy PCxx links.
Neither a relay node's address nor a skimmer spot is sent as a spotter IP.
The pending My Connections first-hover duration correction is included.
G1TLH's cited topology trace names 6.6.20.0; .31 needs fresh bilateral
handshake/topology and spot-format observation by Dirk. No live peer test or
UI walkthrough was run while preparing this kit.
For Dirk's next test, connect to the existing public port 9000 (NC7J-3),
confirm prompt PC22 and sustained PC92 in both directions, then check that
the PC9x link has no PC16/17/19/21 topology dump. If ordinary live spot
traffic includes PC61, confirm its IP survives a PC9x hop with H decremented.
Observe only real traffic; do not inject test spots into public peers.

New in 6.6.30: ARC-tag negotiation for upgraded ARX node peers, with the
four-part ARC release and explicit ARC_TAGS_1 capability in legacy login XML.
No version threshold forces a tag switch. Incoming ARC_Node_* is accepted
only after negotiation; old peers keep AB5K_Node_* traffic. See
ARX-TAG-NEGOTIATION.md in the source workspace. Health now labels its feed
count RBN Feeds. This source also includes the pending .30 Health graph/toolbar
and RBN hostname classification follow-ups.

K1TTT prerequisite context: the September 21 diagnostic selected Dave's
installed 6.1 ArcEngine.dll. Its decompiler-only type lookup failed before
license reading, so it did not explain the earlier staged-upgrade failure.
This kit copies 6.6.33 ArcEngine.dll into an isolated working copy before
running UpgradeLicenseProbe there; the probe now reports that assembly version
and its failure stage/type/HRESULT. If a prerequisite fails, retain the support
ZIP and inspect UpgradeLicenseProbe.err.txt. The optional included
diagnose-upgrade-license.ps1 must target that failed working directory.
Do not direct it to the untouched 2012 installation.

Earlier .30 focused local prerequisite check: the x64 6.6.30 UpgradeLicenseProbe read the
exact K1TTT License.art bytes from his earlier support ZIP, reported
UPGRADE_LICENSE|ENGINE_VERSION|6.6.30.0 and
UPGRADE_LICENSE|PASS|call=K1TTT|preserved|noServerStart. The copied license
hash was unchanged and the temporary copy was removed. This does not prove
Dave's host-specific upgrade path or later database migration will pass.

New in 6.6.29: My Connections keeps the original ARC6, ARC4, Telnet and RBN
artwork and uses distinct 16-pixel incoming/outgoing PCXX arrows. Hover tips
show connection time and duration rather than an internal connection ID.
Tools now shows Open Log Viewer above Logging Options. A Telnet session that
submits the same command nine times within two seconds is disconnected with
one WARN containing callsign, remote IP seen by the server, session ID,
sanitized command, running/queued counts and action. Pending commands for a
disconnected Telnet session are cancelled; an active command may finish.
This gate is per session. Ordinary periodic SH/DX requests are unaffected.

Live .27 evidence: a session signed in as PD2TX sent 32, 52 and 65 identical
`sh/dx 300` requests in about one second at 20:25, 20:30 and 20:35 UTC.
At 20:35, CPU stayed elevated for seconds after the session disconnected.
The client may be retrying on delayed responses; do not infer intent by the
callsign holder. W2ADX made one SH/DX request per five-minute session, and
its 100 response rows matched the configured maximum. See
USER-COMMAND-FLOOD-BACKLOG.md for future escalating-lockout ideas after PC9X
validation. The operator requested a fresh PC9X check from Dirk G1TLH;
feedback is pending. The splash-screen font and collaborator layout request
is deferred to a later build. All UI acceptance remains operator-owned.

New in 6.6.28: Health body labels, chart labels, and bold section titles
are assigned the same explicit 10.25-point font. The Collapse Health
button is wider in a 50-pixel top toolbar so its label has enough room.
This UI correction remains operator-owned for manual acceptance.


New in 6.6.27: restored 16-pixel base artwork in My Connections with
scaled icons when its font grows, stronger direction markers, node tooltips,
and bold peer/RBN labels. Health regular text is larger and Collapse is at
the top right. About text is larger. These UI changes await operator review.

Latest decompiled comparison: the original connection list used 16-pixel icons
and 20-pixel rows, and its hover tips were enabled only on AB5K. The .26
candidate used 28-pixel icons. The .27 revision restores the original visual
scale while keeping the .26 direction distinction and enabling descriptions
for every node. Health and About size/layout changes are intentional updates
to the enhanced candidate views.


New in 6.6.26: RBN portable numeric suffixes use the base call for US/VE
spotterstate lookup while retaining the received spotter and local-only routing.
Health has CPU before threads, larger text, and a Collapse control to retain
the right auto-hide tab. Tools > Logs now presents capture and duplicate
options directly in groups. About and splash include G1TLH and K7CO; About
has more space for warranty text. My Connections icons show direction, with
outgoing PCXX classified correctly. UI acceptance is operator-owned.

Latest decompiled comparison: DX spotter callbook search included /<area>;
Health graphs and collaborator overlay are candidate additions; Logs was a flat
diagnostic list; PCXX outgoing was incorrectly classified as incoming in both
recovered and candidate code. These are intentional improvements.


New in 6.6.25: an enabled RBN telnet feed with an established but silent
connection is disconnected and retried after 60 seconds without received
data. The existing minute timer performs the check, so detection can take
roughly one to two minutes. ArcServer.log records a WARN with the feed identity.
Other outgoing connections do not use this inactivity rule. The feed Health
last-spot timestamp now advances when an RBN DX line arrives. Manual and live
acceptance remain with the operator; no remote setting is changed by the kit.

CURRENT TRIAL PLAN: The operator has .27 on main NC7J and .26 on NC7J-3,
NC7J-5 and NC7J-7, and requested this .29 kit for all four. Upgrade one stopped
instance at a time. It contains all PC9x changes through .23 plus .24 logging persistence
and .25 RBN inactivity reconnect. Preserve each instance's configuration,
license, current data and rollback evidence. Confirm its own callsign, version,
listeners, expected users, peers and feeds after restart before moving to the
next instance. Keep public PCxx port 9000 forwarded to NC7J-3; the kit does
not alter forwarding or peer configuration. Check SHOW PC9X and Health on each
instance with PCxx peers. A peer showing Legacy fallback is not bilateral PC9x
acceptance. Watch for queue growth, route loops and duplicate traffic before
continuing the sequence. Compare the five-minute CPU pulse at similar
feed/user load after upgrading main NC7J. Review the command-flood WARN if
the offending client behavior recurs.
The older NC7J-3-only checklist below documents the initial PC9x trial; it is
not a restriction on this four-instance installation.

New in 6.6.24: the nine Logs > Capture & Diagnostics selections are stored in
the instance's ArcServerCfg.xml and restored at startup. An older configuration
with no AppLog section defaults all nine to off. Menu changes save immediately
without web registration; a failed save restores the prior in-memory choice and
shows an error. The application log severity is unchanged. ProtocolTraffic.log
still rolls at 10 MB with five backups, so persistent capture can fill that
window sooner. Select PCxx/ARX logging once after upgrading from .23; the
runtime-only choices from .23 were not saved. Manual UI acceptance remains with
the operator. The .23 fallback fix and .22 queue fix are included. Keep the
ongoing .23 NC7J-3 soak intact until its data is sufficient; no automatic
installation or restart is part of this kit.

New in 6.6.23: recognize DXSpider's observed oldstyle fallback notice on
incoming and outgoing PCxx sessions. The local session switches to Legacy,
withdraws its PC92 topology and sends one legacy topology snapshot. Future
topology publications use legacy PC16/17/19/21. SHOW PC9X identifies the
fallback reason and counts PC92 frames received after the handshake; a local
Pc9x label alone remains insufficient to prove bilateral acceptance. Install
only on NC7J-3 for this trial. Leave public port 9000 forwarding as currently
configured. After installation, check that W3RGA-1 reports Legacy and receives
no PC92 following its fallback notice. Inspect DH1TW-2 separately; its remote
fallback has not been confirmed. UI acceptance is manual.

New in 6.6.22: resolves a reproduced topology-projection bottleneck on the
protocol worker. Reuse projected node/user objects, index identities once, and
compute routes once per projection. In an isolated 330-node/6600-user fixture,
48 queued topology changes followed by a handshake drained in about 1 second
versus 21.2 seconds on .21. Production acceptance still requires a live trial.
SHOW PC9X reports pending count, oldest age, active duration, last and peak
queue wait. These describe processing delay; capacity=0 alone is not sufficient.
Peer clock diagnostics now use receipt time. Freshness/replay rejection still
uses processing time. No relaxation for delayed or stale topology.
The .22 queue fix is included in .23. Enable logging after startup, connect
the baseline peers and incoming DXSpider peers, and verify prompt PC22 plus
queue waits that drain back toward zero under ordinary live traffic.
The preceding .21 investigation text below is historical; its missing-response
limitation is now supported by measured local queue delay and an offline fix.

New in 6.6.21: follows DXSpider mojo send_local_config ordering: A, K, then
PC20 (outgoing) or PC22 (response). A PC20 after an earlier PC22 or repeated
PC20 still receives a response. Pending PCxx peers are excluded from legacy
topology publications until negotiation completes. Periodic K remains enabled.
SHOW PC9X now includes PC20-rx, PC22-rx and PC22-tx counters.
Dirk's missing live PC22 on .20 was confirmed in logs, but the isolated replay
of that first exchange already passed on .20; its exact cause is unresolved.
This build fixes proven sequence defects, not a claimed live resolution.
After installation, capture a fresh incoming GB7TLH-4 A/K/PC20 exchange and
verify NC7J-3 returns A/K/PC22 and Dirk's side reaches normal. Keep the initial
trial on NC7J-3. NC7J-5/-7 are operator-reported on .20; main NC7J on .16.

New in 6.6.20: fixes incoming PCxx CRLF framing. The listener removes exactly
the delimiter CR before logging/dispatch and ignores empty completed lines.
It preserves payload whitespace and embedded controls for strict validation.
After the baseline below, redirect one incoming peer at a time to the configured
PCxx listener (NC7J-3 port 9002 in the operator's current setup). W3RGA-1 and
DH1TW-2 fixtures now complete A/K/PC20 -> PC22 and receive ordinary PC61 spots.
Check SHOW PC9X for Pc9x connected, no repeated initialization/legacy dump,
ordinary spot delivery and stable counts. Retain the original forwarding rules.
Peer configuration may still name NC7J: validate remote identity/routing in the
live trial rather than assuming port redirection proves full interoperability.

New in 6.6.19: SHOW PC9X reports per-peer accepted/duplicate/rejected counts,
rejection reasons, last queued protocol activity, C/K receipt counts and clock
offset. Two progressing self keepalives from a CC-Cluster banner can establish
a stable quarter-hour offset, pinned for that connection. Only that direct
peer's own PC92 is adjusted locally for freshness/replay evaluation. No wire ID
is rewritten; adjusted topology is not forwarded as PC92 or legacy topology.
Transit PC92 and PC93 remain strict UTC. Clock jumps require reconnect and new
proof. Full CC-Cluster mesh behavior remains a live acceptance gate.

Includes PC92 topology, PC61/PC93 companion messages, per-peer negotiation, legacy
bridging, TALK/CHAT, SHOW PC9X and suppression of empty PCxx publications.
Existing idle transport keepalives remain. See the live-test checklist below.

HISTORICAL NC7J-3 PC9x CHECKLIST (initial trial stages; see current plan above)
1. Save a current stopped-instance backup and record NC7J-3's version and peers.
   Pause its automatic peer reconnects before installing; keep other instances
   running. Install manually, confirm 6.6.29.0, and start with peers disconnected.
2. In Setup, expand PcxxCfg: EnablePc9x defaults true; ensure
   IgnoreNodeUserProtocol is false. I/O clients/listeners set to PCxx are eligible
   automatically. Pc9xPeers is obsolete, hidden and ignored. The outgoing
   ConnectAs identity remains NC7J-3, registered as an AR-Cluster node on NG7M-1.
   Keep the existing AI9T endpoint. Use NG7M-1's reachable DXSpider address/7300;
   do not assume raspi5-1 resolves from NT7G-SERVER. Save before reconnecting.
3. Enable Log PCxx if needed; from .24 onward it persists. Record start/end times and
   collect ProtocolTraffic.log, ArcServer.log and a Health report for each stage.
   Confirm rolling log size/retention is adequate; turn verbose capture down
   after evidence is collected. Captures can contain user messages/IP addresses.
4. Connect ONLY NG7M-1 for 10-15 minutes. From a local user connection run
   SHOW PC9X, SHOW NODES and SHOW USERS. Expect NG7M-1 Pc9x connected, PC92
   proof and PC22, normal spots, stable counts/CPU and no repeated initialization.
   Disconnect/reconnect once; confirm its old routes clear and then rebuild.
5. Disconnect NG7M-1; connect ONLY AI9T for 10-15 minutes and repeat those checks.
   AI9T is the first real CC-Cluster acceptance gate. Legacy mode means fallback,
   not successful PC9x interoperability; save its exact PC18/92/20/22 sequence.
   With the observed AI9T pair, expect clock-adjustment=18000s and at least one
   adjusted-local record after the second progressing K. PC92-C=0 means no
   configuration was received; accepting keepalives does not prove topology.
6. If both pass independently, connect BOTH for 30-60 minutes. Watch for
   recurring PC16/17 echoes, duplicate spots/messages, route/count growth,
   repeated reconnects, rising CPU or queue backlog. Drop/reconnect one link
   once: routes reachable through the other should survive. Initial sparse
   topology and deletes for not-yet-learned entries are not by themselves failure.
7. Keep NC7J-3 free of ordinary users during the initial stages. Then use one
   local test login and, with a cooperating recipient, one directed TALK/reply.
   Do not send synthetic spots, broadcast test announcements or load traffic
   into the public network. Skimmer/-# spots must never leave for either peer.
8. After the short stages pass, leave an attended observation period of at least
   4-6 hours to include periodic PC92 refresh and expiry behavior. Avoid adding
   other peers until this two-peer baseline is accepted.
STOP: sustained loops/flooding, a crash, growing queues/CPU or broken normal
delivery. Disable the trial peer links, retain logs, and report the stage/time.
If needed restore the current stopped-instance backup using the established
rollback procedure. Setting EnablePc9x=false plus reconnect selects legacy; it does
not repair the legacy topology-loop behavior that prompted this work.

Local evidence: 136 actual-assembly integration checks per architecture, including
incoming framing and both captured handshakes. Unchanged protocol core previously
passed 423 checks per architecture. Earlier short NG7M-5 -> NG7M-1
DXSpider trial passed. This is not yet CC-Cluster or sustained mesh acceptance.

Before starting the new version, preserve a CURRENT offline copy of the selected
installation and databases, in addition to the installer's original baseline.
The baseline may predate recent data. Rollback of executables alone cannot undo
history pruning. Observe the first hourly trim and check SH/DX, the Setup label,
and newly written logs with Log PCxx off. Existing log entries remain visible.
The operator handles install/rollback acceptance; no automated 6.6.17 upgrade
rehearsal or UI acceptance is claimed. Dave may use this identical host-neutral
kit with his own installation and license; retain the generated support ZIP if
prerequisites fail. The earlier K1TTT host-specific failure is not yet resolved.

Development candidate: x64 builds, local database/capacity checks and isolated
ARC4 export pass. Clean-host prerequisites and manual UI gates remain open.
ARC4 export uses Tools/Arc4Export/Arc4ExportWorker.exe and the existing x86
OLE DB provider. Keep this worker with the package; no provider is installed.
Deployment requires the operator's instance-specific authorization. Keep older
x86 kits and rollback evidence unchanged. Program Files (x86) relocation and
installation path changes are described in INPLACE-QUICKSTART.txt.

The checklist above describes the earlier NC7J-3-only trial. Use the current
four-instance plan at the top for the 6.6.25 operator rollout.

Before the maintenance window, record:
- Exact installation directory and current displayed/file version: pending.
- The working directory used by the existing shortcut/service: pending.
- Expected peers, feeds and usual user count; save a baseline Health report if available.
- The supplied ZIP hash and its matching candidate receipt.

Extract the complete kit to a short writable directory on the installation drive,
outside the installation. Run this read-only command from Windows PowerShell 5.1:

    powershell.exe -NoProfile -ExecutionPolicy Bypass -File .\preflight-trial.ps1 -InstallationDirectory "<existing installation>" -WorkingDirectory "<actual working directory>" -CheckLiveState

Keep the output private: it includes local paths. Review every finding. Preflight
checks readability, locations and space estimates; it does not certify database
integrity or authorize installation. License identity is checked in the isolated
upgrade stage. No replacement license or hostname registration is required.

The optional -CheckLiveState adds a local process/listener snapshot. Review
LiveState.StoppedState and OccupiedEndpoints separately: an occupied port is not
proof that this instance owns it. Unknown/unavailable results need local review;
NoMatchingProcessObserved is only a momentary observation.  Recheck immediately before maintenance.
PreflightClear describes file/host preparation only, not permission to upgrade.

Rollback.Status distinguishes an unrecorded baseline, a recorded-but-unverified
baseline and a state needing review. A pending recovery journal blocks preparation
regardless of that status. The installer still verifies baseline files and identity.
SupportFiles reports missing/empty DxCluster.dat or logging configuration as warnings;
the preflight does not download replacements or change existing operator settings.

During the chosen maintenance window:
1. Stop this instance normally.
   Confirm its users/peers will be interrupted; leave other instances unchanged.
2. Start ARC6-Upgrade.exe and select that exact installation root.
3. Read the final result and retain its evidence path. Do not launch ARC6 while
   the upgrade is running or if a pending recovery journal remains unresolved.
4. Only for an operator-selected *new* ProgramData canary, complete the migration
   at the top of this handoff while ARC6 remains stopped. For K1TTT's CPU
   comparison, skip migration. Then start ARC6 normally. Confirm version, licensed identity,
   listeners, expected peers/feeds and reconnecting users.
5. Manually check Health scrolling, command counters, About and protocol viewer.
   For I/O changes, verify enable/disable and deletion when Setup closes; use a
   disposable local test device for an occupied-port warning. Do not delete a
   production device merely to test the UI. No automated UI acceptance is claimed.

Observe the first hour: save a Health report after reconnects settle and near
15, 30 and 60 minutes. Compare CPU, memory, handles, errors, history saves and
thread trend with the current user/feed load. A retained idle thread pool alone
is not a restart trigger. Note configuration changes alongside their timestamps.
Watch through ordinary scheduled maintenance; no synthetic public load is needed.

If problems affect service, retain logs and the upgrade evidence, then choose
rollback during a maintenance window. Stop ARC6 first. Use the kit's Rollback
operation against the same installation and read its result before restarting.
The retained baseline is the original baseline, not necessarily the immediately
previous trial. Rolling back restores that snapshot and can discard newer state;
retain a separate copy of current data before choosing rollback. An unresolved
journal requires the documented Recover/status workflow, not manual folder moves.

This trial uses the managed Log Viewer and retains existing License.art runtime behavior.
No capacity guarantee, automatic monitoring or remote deployment is implied.
